The EA2 series is available in 2 form C (DPDT) contact arrangements for all latch types.
The NEC EA2 series relays are low power consumption, low magnetic interference relays. Their compact lightweight design makes them ideal for use in telecommunications equipment. This series also complies with FCC Part 68 1500V surge voltage requirements.
Low power consumption
Compact and lightweight
2 form C contact arrangement
Low magnetic interference
Breakdown voltage: 1000 Vac (surge voltage 1500 V), FCC Part 68 compliant
Tube packaging
UL recognized (E73266), CSA certified (LR46266)
Specifications
Contact Form
2 form C
Contact Material
Silver alloy with gold alloy overlay
Contact Ratings
Maximum switching power
30 W, 62.5 VA
Maximum switching voltage
220 Vdc, 250 Vac
Maximum switching current
1 A
Maximum carrying current
2 A
Minimum Contact Ratings
10 mVdc, 10 µA (resistive)
Initial Contact Resistance
50 mOhm typical
Nominal Operating Power
Nonlatch type
Double coil latch type
140 mW (3 to 12 V)
200 mW (24 V)
Single coil latch type
100 mW (3 to 12 V), 150 mW (24V)
Operate Time (Excluding bounce)
Approximately 2 ms without diode
Release Time (Excluding bounce)
Approximately 1 ms without diode
Insulation Resistance
1000 MOhm at 500 Vdc
Breakdown Voltage
Between open contacts
1000 Vac (for one minute)
1500 V surge (10 x 160 µs*)
Between adjacent contacts
Between coil to contacts
1000 Vac (for one minute)
1500 V surge (10 x 160 µs*)