EC2 Series
| | | | | | | |
Features
|
The NEC EC2 series relays are low power consumption, low magnetic interference relays that meet 2500V surge requirements(between coil and contacts). Their compact lightweight through hole lead design makes them ideal for use in telecommunication equipment. This series complies with FCC Part 68 2500V surge voltage requirements.
The EC2 series is available in 2 form C (DPDT) contact arrangements for all latch types.
 
|
- Compact and lightweight
- 2 form C contact arrangement
- Low power consumption
- Reduced mounting space: 15 mm x 7.5 mm
- High-breakdown voltage of coil to contacts: 1500 Vac, 2500 V (2 x 10 µs*)
- Capable of high-power switching: 700 Vac, 4.2 A, 4 times in case of accident
- UL recognized (E73266), CSA certified (LR46266)
- Certified to EN 60950
|
Applications
Electronic switching systems, PBX, terminal equipment, telephone systems.
Specifications
| Contact Form |
2 form C |
| Contact Material |
Silver alloy with gold alloy overlay |
| Contact Ratings |
Maximum switching power |
60 W, 125 VA |
| Maximum switching voltage |
220 Vdc, 250 Vac |
| Maximum switching current |
2 A |
| Maximum carrying current |
2 A |
| Minimum Contact Ratings |
10 mVdc, 10 µA (resistive) |
| Initial Contact Resistance |
50 mOhm typical |
| Nominal Operating Power |
Nonlatch type |
140 mW (3 to 12 V), 200 mW (24 V) |
| Single coil latch type |
100 mW |
| Double coil latch type |
140 mW |
| Operate Time (Excluding bounce) |
Approximately 2 ms without diode |
| Release Time (Excluding bounce) |
Approximately 1 ms without diode |
| Insulation Resistance |
1000 MOhm at 500 Vdc |
| Breakdown Voltage |
Between open contacts |
1000 Vac (for one minute)
1500 V surge (10 x 160 µs*) |
| Between adjacent contacts |
| Between coil to contacts |
1500 Vac (for one minute)
2500 V surge (2 x 10 µs**) |
Double Coil: 1000 Vac (for one minute)
Latch Type: 1500 V surge (10 x 160 µs*) |
| Shock Resistance |
735 m/s2 (75 G) (misoperating)
980 m/s2 (100G) (destructive failure) |
| Vibration Resistance |
10 to 55 Hz, double amplitude 3 mm (20 G) (misoperating)
10 to 55 Hz, double amplitude 5 mm (30 G) (destructive failure) |
| Ambient Temperature |
-40 to +85°C |
| Coil Temperature Rise |
18 degrees at nominal coil voltage (140mW) |
| Running Specifications |
Nonload |
1 x 107 operations |
| Load |
50 Vdc, 0.1 A (resistive) 1 x 106 operations at 85°C |
| 10 Vdc, 10 mA (resistive)1 x 106 operations at 85°C |
| Weight |
Approximately 1.9 g |
EC2 Dimensions
mm (inch)

Pad Layout
(bottom view) mm (inch)

Markings

Schematics
(bottom view)

Part Number System
Relay series through hole type
Nominal coil voltage (See nominal lineup)
Latch type
- Blank: Non-latch type (standard)
- S: Single coil latch type
- T: Double coil latch type
Identifier
- NJ: Trimmed leads standard type (UL recognized, CSA certified type)
- NU: UL recognized, CSA certified type
- NC: Ultrasonic cleaning availble type (only non-latch type) (UL recognized, CSA certified type)
- NP: Silver-palladium alloy contact (with gold alloy overlay) (UL recognized, CSA certified type)
Nominal Lineup
Nonlatch Type at 25° C
Part Number
(Standard) |
Nominal
Coil Voltage
(Vdc) |
Coil
Resistance
(Ohm) ±10% |
Must Operate
Voltage
(Vdc) |
Must Release
Voltage
(Vdc) |
| EC2-3NJ |
3 |
64.3 |
2.25 |
0.3 |
| EC2-4.5NJ |
4.5 |
145 |
3.38 |
0.45 |
| EC2-5NJ |
5 |
178 |
3.75 |
0.5 |
| EC2-6NJ |
6 |
257 |
4.5 |
0.6 |
| EC2-9NJ |
9 |
579 |
6.75 |
0.9 |
| EC2-12NJ |
12 |
1028 |
9 |
1.2 |
| EC2-24NJ |
24 |
2880 |
18.0 |
2.4 |
Single Coil Latch Type at 25 °C
Part Number
(Standard) |
Nominal
Coil Voltage
(Vdc) |
Coil
Resistance
(Ohm) ±10% |
Must Operate
Voltage
(Vdc) |
Must Release
Voltage
(Vdc) |
| EC2-3SNJ |
3 |
90 |
2.25 |
2.25 |
| EC2-4.5SNJ |
4.5 |
202.5 |
3.38 |
3.38 |
| EC2-5SNJ |
5 |
250 |
3.75 |
3.75 |
| EC2-6SNJ |
6 |
360 |
4.5 |
4.5 |
| EC2-9SNJ |
9 |
810 |
6.75 |
6.75 |
| EC2-12SNJ |
12 |
1440 |
9.0 |
9 |
| EC2-24SNJ |
24 |
5760 |
18.0 |
18 |
Double Coil Latch Type at 25 °C
Part Number
(Standard) |
Nominal
Coil Voltage
(Vdc) |
Coil
Resistance
(Ohm) ±10% |
Must Operate
Voltage
(Vdc) |
Must Release
Voltage
(Vdc) |
| EC2-3TNJ |
3 |
S 64.3 |
2.25 |
- |
| R 64.3 |
- |
2.25 |
| EC2-4.5TNJ |
4.5 |
S 145 |
3.38 |
- |
| R 145 |
- |
3.38 |
| EC2-5TNJ |
5 |
S 178 |
3.75 |
- |
| R 178 |
- |
3.75 |
| EC2-6TNJ |
6 |
S 257 |
4.5 |
- |
| R 257 |
- |
4.5 |
| EC2-9TNJ |
9 |
S 579 |
6.75 |
- |
| R 579 |
- |
6.75 |
| EC2-12TNJ |
12 |
S 1028 |
9.0 |
- |
| R 1028 |
- |
9.0 |
| EC2-24TNJ |
24 |
S 4114 |
18.0 |
- |
| R 4114 |
- |
18.0 |
Safety Standard and Rating
UL Recognized
(UL508)*
File No. E73266 |
CSA Certified
(CSA C22.2 No. 14)
File No. LR46266 |
30 Vdc, 2 A (Resistive)
110 Vdc, 0.3 A (Resistive)
125 Vac, 0.5 A (Resistive) |
* Spacing: UL114, UL478, UL1950
EN60950
|