UA2/UB2 Series NE Type
| | | | | | | |
Features
|
NEC TOKIN's NE TYPE of UA2/UB2 series is a low-power consumption relay.
 
|
- Small mounting size of slim package for dense mounting.
- Low power consumption 100 mW
- Telcordia (2500 V) and FCC (1500 V) surge capability.
- IEC60950/UL1950/EN60950 spacing and high breakdown voltage.
(Basic insulation class on 200 V working voltage)
|
Applications
Electronic switching systems, PBX, terminal equipment, telephone system.
Specifications
| Contact Form |
2 Form c
|
| Contact Ratings |
Maximum Switching Power |
30 W (resistive)
|
37.5 VA (resistive)
|
| Maximum Switching Voltage |
220 Vdc
|
250 VAC
|
| Maximum Switching Current |
1 A
|
| Maximum Carrying Current |
1 A
|
| Minimum Contact Ratings |
10 mV.dc, 10 µA * 4
|
| Initial Contact Resistance |
100 mΩ Max. (Initial)
|
| Contact Material |
Silver alloy with gold alloy overlay
|
| Nominal Operating Power |
100 mW
|
| Operate Time (Excluding Bounce) |
Approximately 2 ms
|
| Release Time (Excluding Bounce) |
Approximately 1 ms without diode
|
| Insulation Resistance |
1000 MΩ at 500 Vdc
|
| Breakdown Voltage |
Between Open Contacts |
1000 Vac for one minute (1500 V surge, 10 x 160 µs * 1 )
|
| Between Adjacent Contacts |
| Between Coil and Contact |
1500 Vac for one minute (2500 V surge, 2 x 10 µs * 2 )
|
| Shock Resistance |
735 m / s2 (misoperating)
980 m / s2 (destructive failure)
|
| Vibration Resistance |
10 to 55 Hz at double amplitude of 3 mm (misoperating)
10 to 55 Hz, double amplitude of 5 mm (Destructive failure)
|
| Ambient Temperature |
40 to +85°C
|
| Coil Temperature Rise |
12 degrees at nominal coil voltage (100 mW)
|
| Running Specifications |
No-load |
5 x 107 * 3 operations
|
| Load |
30 Vdc 1 A (resistive), 1 x 105 operations at 20°C
|
|
125 Vac 0.3 A (resistive), 1 x 105 operations at 20°C
|
| Weight |
Approximately 1 gram
|
Dimensions
mm [inch]
UA2 Series

UB2 Series
STANDARD

MINIMUM FOOTPRINT TYPE

Pad Layout
(bottom view) mm
UA2 Series

Note: General tolerance: ±0.1
UB2 Series
STANDARD

Note: General tolerance: ±0.1
MINIMUM FOOTPRINT TYPE

Note: General tolerance: ±0.1
Markings

Schematics
(bottom view)
UA2 Series

UB2 Series

Part Number System
Series name
Nominal coil voltage
- A numerical value of coil voltage (See Nominal Lineup)
Option
- NE: Standard
- NEJ: Trimmed lead type of UA2
- NEN: Minimum footprint type of UB2
Package
- Nil: Tube (All of UA2, T be select for UB2)
- L: Embossed carrying tape of L type (UB2 only)
- R: Embossed carrying tape of R type (UB2 only)
- L6: Embossed carrying tape of L type with MBB* (UB2 only)
- R6: Embossed carrying tape of RL type with MBB* (UB2 only)
Nominal Lineup
Non-latch Type
at 20°C
Nominal
Coil Voltage
(Vdc) |
Coil
Resistance
(Ohm) ±10% |
Must Operate
Voltage
(Vdc) |
Must Release
Voltage
(Vdc) |
Nominal
operate power
(mW) |
| 3 |
90 |
2.25 |
0.3 |
100 |
| 4.5 |
202.5 |
3.38 |
0.45 |
100 |
| 5 |
250 |
3.75 |
0.5 |
100 |
Safety Standard and Rating
UL Recognized
(UL508)*
File No. E73266 |
CSA Certified
(CSA C22.2 No. 14)**
File No. LR46266 |
30 Vdc, 1A (Resistive)
110 Vdc, 0.3 A (Resistive)
125 Vac, 0.3 A (Resistive) |
Recommended Relay Drive Conditions
Drive under conditions. If it is impossible, please inquire to NEC/TOKIN
Nonlatch type
(Low power consmuption) |
Pulse height : within ±5% at nominal voltage
Square pulse (rise and fall time is rapidly) |
Ambient temperature
40 Å` +85°C |
Performance Data
Coil Temperature Rise
Temperature is measured by coil resistance.
Switching Capacity
This is allowed maximum value. Inquiry for NEC/TOKIN under maximum value at continuous use.
Maximum Coil Voltage
This is a maximum value of permissible alteration. Inquiry for NEC/TOKIN at continuous use.
Applied Voltage Vs. Timing (Sample : UA2-5NE)
Operate and Release Voltage Vs. Ambient Temperature
This shows a typical change of operate (release) voltage. Maximum value of operate is estimated, so it must be applied more than this value for safety operation. In case of “hot start operation”, please inquiry for NEC/TOKIN.
Running Test (Nonload)
(Load : None, Driving : 5V. DC, 50Hz, 50%duty, Ambient temperature : Room temperature, Sample : UC2-5NU 20 pieces)
Running Test (Load)
(Load : 50V. DC 0.1A resistive, Driving : 5V. DC, 5Hz, 50%duty, Ambient temperature : 85 degree C, Sample : UA2-5NE 10 pieces)
Breakdown Voltage
Sample: UA2-5NE 10 pieces
Alternation of Voltage at Densely Mounting (Magnet interference)
Tube Package (UA2, UB2)
Dimension of Package (Unit : mm)
Outline of Package
Tape Package (UB2)
Appearance
Tape Dimension mm (inch)
Relay Orientation Mark and Tape Carrying Direction
Soldering Temperature Condition
Through-hole mounting type (UA2)
Automatic soldering
- Preheating : 100°C max. 1 minute max.
- Solder temperature : 260°C max.
- Solder time : 5 seconds max.
Manual soldering
- Solder temperature : 350°C max.
- Solder time : 3 seconds max.
Surface mounting type (UB2)
IRS Method
|