3. Notes on Driving Relays

(1)  Temperature characteristics

If the relay is used at an ambient temperature exceeding the operating temperature range, the performance of the relay may be degraded and the life may be dramatically shortened.
 

  (A)  It is possible to use the relay at the rated coil voltage within the operating temperature range. Note, however, that at the upper limit of the operating temperature range, the permissible voltage on the coil may be restricted, and must be confirmed before the relay is used.
 
(B)  The must operate voltage, must release voltage, operate time and release time, change with the ambient temperature. Refer to Technical Documents to confirm that the relay operates normally at a particular operating temperature. Fig. 4 shows an example of the temperature characteristics of the relay.
 

Fig. 4 Temperature Characteristics of Relay (Example)

(2)  Maximum applied voltage

The permissible maximum applied voltage of a given relay coil changes with ambient temperature. The coil temperature rise (the self-heat temperature, i.e., the applied-voltage-dependent portion) is the difference between the permissible temperature specified by relay design and the operating temperature.

Refer to the coil voltage vs. temperature derating characteristics in the Technical Documents for this value. An example is shown in Fig. 5.

The permissible temperature of relay operation is determined mainly by the coil wire and plastic materials used. In the case of the NEC Miniature Signal Relays, the standard specification is set at 120°C.

As the applied coil voltage increases, the operate time becomes shorter. However, the bounce in the make contacts becomes longer, increasing the contact opening or closing frequency. This may affect the life of the contacts.
 

Fig. 5 Coil Voltage vs. Ambient Temperature Derating Characteristics (Example)

(3)  Hot Start

When the temperature of the relay has risen due to heat generated by the coil being energized, the relay may not operate if the coil is de-energized and then immediately re-energized. This is because the coil resistance increases due to heat, causing the current to fall when applied voltage remains constant. This phenomena is called a hot start. This occurs when the operating temperature is high, and a voltage lower than the specified coil voltage is applied. It is necessary to refer to Technical Documents to know in advance the must operate voltage at a given temperature in order to prevent this phenomena.
 

(4)  Non-must operate and holding voltages

In some circuits, the relay must not operate at a certain voltage or release at a certain voltage. Contact World Products for a product specification outlining non-must operate and holding voltages.
 

Fig. 6 Example of Distribution of Relay Must Operate Voltage and Must Release Voltage

(5)  Drive waveform

The relay will not operate correctly if coil drive waveform gradually increases and decreases. The voltage must instantaneously rise and fall as a pulse.
 

Fig. 7 Relay Drive Waveform

(6)  Latching relay drive circuit
 
  (A)  Since the relay coil has an inductive impedance, a counter electromotive force is generated when the circuit is opened.

This voltage may damage the relay driver transistor, therefore a diode should be connected in parallel with each coil. With a single coil latching type relay a diode cannot be used because the current direction of the coil inverts, a transistor with sufficient reverse breakdown voltage should be used instead.
 

  (B)  A latching relay is driven by a coil voltage pulse. The pulse width of this drive voltage must be 10 ms or wider. If the pulse is too short, the relay may not operate correctly.
 
  (C)  If the coil of a relay is polarity sensitive, be sure to apply the coil voltage correctly. With a double coil latching type relay, do not apply voltage in a manner that both the set and reset coils are energized at the same time. (Refer to Fig. 8.)
 

Fig. 8 Drive Circuit of Latching Relay (Example of Double Coil Latching Type)

  (D)  A latching relay is factory-set to the reset state for shipment. However, it may set while being transported due to vibration or shock. Make sure the relay is reset when its application system starts operating. When the relay is employed in a portable system, the circuit must be designed so the relay is reset at the beginning of operation since the relay may set due to unexpected vibration or shock.
 
(7) Connection of coil diode

Inductive loads, such as solenoids and electromagnetic clutches produce a large energy discharge when the contacts open. A Zener diode should be connected with the drive transistor to prevent damage.

When a diode is connected in parallel with the coil, the current in the coil diminishes gradually when the relay releases. This may slow down the opening of the normally open contacts thereby increasing their wear.
 

(8) Opening/closing frequency

If the contacts are opened or closed frequently with a high current load, repeated electric discharges may cause contact metal deposition or damage to the contact spring. When frequently switching a high current load consult World Products for technical data.
 

(9) Continuous energizing of coil

If the coil is energized for long periods of time the coil temperature may rise. This promotes the generation of organic gas within the relay. This can cause trouble with contact stability. When using a circuit that requires the coil to be constantly energized, consider the possibility of using a latching relay. Latching type relays do not require constant energy to hold the same operating state as the non-latching types.
 

(10)  Instantaneous voltage drop of circuit

When the same power source is used for both the load and relay drive circuits, care should be taken when switching a load with a high inrush current such as a lamp load. The source voltage may drop if the power source capacitance is small resulting in a case where, the relay may release or an oscillation phenomenon occurs.

Power source capacitance or a smoothing circuit should be added to prevent this phenomenon.
 

1. General
Back to: 2. Notes on Contact Load
Forward to:  4. Notes on Operating Environments
5. Influence of Relay Operation on Surroundings
6. Notes on Mounting
7. Notes on Cleaning
8. Notes on Handling Relays
9. Notes on Using SMT Relays